Секундарне фреквенције

Квалитет електричне енергије у немачком преносном систему — надзор великих размера, Анализа корелације, и дугорочне прогнозе

85 ИЕЦ 61000-4-30 Class A monitoring sites across 50 substations in the German transmission system — 38 у 110 кВ, 21 у 220 кВ, 26 у 380 кВ. Hierarchical clustering reveals which sites are redundant and which are uniquely informative. Ensemble forecasting of weekly 95th-percentile PQ parameters outperforms any individual model. The first dataset to demonstrate systematic, recurring PQ correlation structures at transmission level driven by inverter-based generation.

АИ центри података и квалитет електричне енергије — Нова категорија поремећаја у мрежи

AI training clusters create a load type that did not exist when power quality standards were written: synchronised GPU operation producing oscillatory load signatures with 10+ MW/second ramps, harmonic THD exceeding 5%, and simultaneous UPS disconnection risk of 2+ GW in dense data centre corridors. A real Dominion Energy grid event was triggered by a data centre producing a voltage sag at precisely once per second. Three open-access papers from 2025–2026 document the scale of the problem and the mitigation approaches now being required by grid operators.

Квалитет електричне енергије у систему дистрибуције електричне енергије академске институције — Универзитет Султан Кабус

Full campus PQ audit at Sultan Qaboos University, Oman — 33 kV/11 kV/415 V distribution system. Non-linear loads: PV inverters, UPS systems, VFD chillers, and hundreds of switch-mode power supplies in computer labs. THDI ranged from 2–10%, TDD from 2–8% across measurement points. Main substations compliant with IEEE 519 due to harmonic aggregation cancellation — but individual buildings exceeded 8% at peak load. Key lesson: the THD vs. TDD distinction prevents false alarms. The study establishes a pre-DER baseline before planned large-scale PV integration.

ЕВ пуњење и квалитет електричне енергије у ЛВ стамбеним мрежама — од појединачног пуњача до продора у флоту

Level 2 EV chargers at 7.2 kW produce third-harmonic dominant current that accumulates in the neutral conductor and causes voltage unbalance increasing with distance from the transformer. Monte Carlo simulation across multiple penetration levels shows uncontrolled charging at 30%+ penetration can push VUF beyond 2% at feeder end buses. Smart charging eliminates the problem without hardware mitigation. EV chargers also produce supraharmonic emissions (2–150 kHz) that can disrupt the PLC communications intended to manage EV charging itself.

Пуњачи за електрична возила и квалитет електричне енергије у домаћинствима — двонедељна теренска студија

Two-week field measurement at a residential condominium in Bangkok. Single-phase EV chargers created phase imbalance, neutral current overloading, and current THD of 15–20% during charging. Peak voltage unbalance reached 2.18% — at the EN 50160 лимит. Retrofitted infrastructure not designed for EV loads.

Процена квалитета електричне енергије заснована на подацима у болничком електричном систему

Full PQ audit at University of Lampung Hospital, Индонесиа. Voltage and frequency compliant at the meter — but current TDD exceeded IEEE 519 limits many times over, voltage unbalance non-compliant, power factor lagging. All problems originated inside the facility from non-linear loads: СМПС, УПС, ВФДс, imaging equipment.

Проблеми са квалитетом електричне енергије у медицинским установама — квар ЕКГ-а

A hospital EKG machine produced unreliable results. Signal wiring routed parallel to the power cord created inductive coupling — a classic internal EMC failure invisible to utility PQ standards. Root cause: wiring practice, not utility supply quality. 75% of medical facility PQ problems are internal wiring and grounding issues.

Амазинг Интл – Оптимална ефикасност трансформатора коришћењем пондерисаног просечног оптерећења: Беионд ДОЕ 2016

Mirus International demonstrates why DOE 2016 transformer efficiency ratings miss the mark for harmonic-rich environments. Weighted average loading at harmonic-producing loads requires adjusted efficiency equations — the ULLTRA transformer design achieves high efficiency across the full load spectrum, not just at nameplate rating.

Амазинг Интл – Генератори и нелинеарна оптерећења: Како хармонично ублажавање елиминише захтев превелике величине

Mirus International demonstrates that generators feeding non-linear loads must be derated or oversized to prevent excessive voltage distortion — standard practice adds 20–25% generator capacity. The Wide Spectrum Filter (Lineator) eliminates the oversizing requirement by reducing harmonic current drawn from the generator, enabling right-sized generator selection and significant capital and fuel savings.

Амазинг Интл – Пасивно вс. Активни хармонијски филтер у центру података: Поређење терена

Пасивно вс. active harmonic filter comparison at a New Jersey data centre: active filter failed repeatedly at this site, passive Lineator filter installed on the same VFD loads achieved THID below 5% — well within IEEE 519 — and has operated without failure for years. The case presents measured data from both technologies on the same equipment at the same site.

Амазинг Интл – Синусни филтер вс. дВ/дТ филтер за ВФД апликације дугих каблова: Непосредно поређење на терену

Long cable VFD applications produce cable resonance that amplifies dV/dt at the motor terminals — causing insulation stress and premature motor failure. A dV/dt filter limits the voltage rise rate but does not produce a true sine wave. A sinewave filter eliminates both the resonance and the harmonic content. Field comparison at San Antonio Water Authority shows measured motor terminal voltage for both filter types.

Амазинг Интл – Ефикасност турбо вентилатора и хармонична усклађеност у комуналном постројењу за отпадне воде

Municipal wastewater plant with turbo blower VFDs: total harmonic current distortion exceeded IEEE 519 limits at the point of common coupling. Three-party solution — utility, municipality, and Mirus — achieved ITDD (Individual Total Demand Distortion) compliance using Lineator filters. Efficiency improved and the plant qualified for utility incentives unavailable under non-compliant harmonic conditions.

Амазинг Интл – Хармоничка усклађеност за девет Панамак бродова за расути терет: ЦСЛ група и морски пут Великих језера

Nine Panamax bulk carriers in the CSL Great Lakes Seaway fleet were found non-compliant with Lloyd’s Register harmonic requirements during routine inspection. VFD-driven loads on each vessel were generating harmonic currents exceeding the limits. Mirus Lineator filters brought all nine vessels into compliance — documented with before/after measurements on representative vessels.

Амазинг Интл – Хармонично управљање на даљинском нафтном бушотину: Перформансе боље од 18 импулса по цени од 12 импулса

Remote oil well site with a single-drive VFD application: multi-pulse transformer approaches were impractical at this location. Mirus Lineator passive filter achieved better than 18-pulse harmonic performance at 12-pulse cost — measured THID below 5% at the drive input. The case demonstrates that passive harmonic filters can outperform multi-pulse transformers in single-drive, isolated applications.

Амазинг Интл – Хармонично ублажавање за контролни центар мотора са напајањем од генератора: Фабрика заслађивања природног гаса

Natural gas sweetening plant with a generator-fed motor control centre: the generator’s high source impedance amplified harmonic voltage distortion from VFD loads to levels that caused control system malfunctions. Mirus filter selection had to account for the generator impedance characteristics rather than infinite bus assumptions — a common oversight in generator-fed harmonic filter design.

Амазинг Интл – Хармонично ублажавање морских обавеза штеди програм за пловно пловило на мору

An offshore service vessel DC drive system produced voltage notching severe enough to cause control system malfunctions on other vessel systems. The vessel program was at risk of cancellation. A Mirus Lineator filter on the DC drive eliminated the notching — restoring compatibility between the drive and the vessel’s sensitive electronics. Documented with oscilloscope waveforms before and after.

Амазинг Интл – Хармонично ублажавање и подешавање величине генератора – Студија случаја пумпне станице за цевовод

Pipeline pumping station with generator-fed VFDs: harmonic current from the drives caused the generator to be significantly oversized — adding capital cost and reducing fuel efficiency. Mirus sinewave filter reduced harmonic current to allow generator rightsizing, improving fuel efficiency and reducing the generator procurement cost. Field results show measured harmonic distortion and generator loading before and after.

Амазинг Интл – Синусни филтери за ЕСП заштиту мотора: Студија случаја на терену у дизајну филтера и термичком одговору мотора

Submersible ESP (Electric Submersible Pump) motors fed via VFDs through long cables: sinewave filter design must account for the cable capacitance, motor inductance, and the filter’s own resonant frequency. Incorrect filter design can produce resonance at a harmonic frequency, amplifying distortion rather than reducing it. Case documents the filter design process and measured thermal response of the motor under harmonic loading.

Практична Случај Повер Куалити Студи (Маслиново дрво, Јосе Ц.)

IEEE conference paper by Prof. José Carlos de Oliveira (Federal University of Uberlândia) — site measurements at a Brazilian textile factory. Four-parameter framework: voltage profile, хармонијске дисторзије, напон дебаланс, and feeder transfer risk. A foundational industrial PQ assessment methodology paper. The PDF is available for download from the IPQDF library.

Идентификација нездравих електроенергетских система са не-Цхаратеристиц хармоника

Non-characteristic harmonics — orders not predicted by the standard 6k±1 formula for 6-pulse rectifiers — appear in power systems with converter firing angle asymmetry, supply unbalance, or multiple overlapping non-linear loads. Schlumberger/IEEE paper presents an identification methodology using harmonic fingerprinting to detect unhealthy power systems from their non-characteristic harmonic signature.

Хармоници Студија случаја

A major food processing and distribution centre in Dortmund, Germany — 100,000 m² facility — experienced production disruptions and equipment malfunctions from harmonic distortion generated by VFDs in the highly automated facility. Active harmonic filter installation reduced current THD and eliminated the production disruptions. Before/after measurements confirm compliance with German grid code.

Хармоници Ублажавање на ВФД

GRYAAB Gothenburg sewage works used variable-speed pumps to process wastewater — but VFD harmonic currents limited pump output to below the theoretical maximum. Active harmonic filter installation optimised VFD electrical behaviour, enabling 30% more throughput during peak demand periods. Energy savings were a secondary benefit — the primary gain was process capacity.

СТАТЦОМ Студија случаја

Europe’s largest steel wire producer faced a tightened flicker limit from the utility as local grid usage increased. Spot welders from Schlatter AG produced flicker emissions exceeding the new limit. A STATCOM installation reduced flicker to compliant levels — the case documents the assessment methodology, STATCOM sizing, and before/after measurement results.

Хармоници и пазов у ​​динамички тест оптерећења

A major European manufacturer’s dynamic test bench — with highly variable loading — produced harmonics up to and beyond the 100th order plus voltage notching that corrupted test results. Active harmonic filters compensating up to the 100th order eliminated both phenomena, restoring the integrity of development testing and preventing false test failures from power supply artefacts.

Активни Хармонични Филтери у штампи Апплицатионс

Amsterdam printing company producing 1 million papers daily with presses running almost continuously experienced PQ problems manifesting as production downtime and fluorescent lighting interference. Active harmonic filter installation reduced current THD, stabilised voltage, eliminated the lighting flicker, and reduced measured downtime. Before/after voltage waveform comparison shows the improvement.

Хармоници генерација, Размножавање и Технике чишћења у не-линеарна оптерећења

Saudi Arabia academic review of harmonic generation mechanisms, propagation paths, and mitigation techniques for non-linear loads — covering passive filters, active filters, hybrid approaches, and multi-pulse converters. Provides theoretical grounding for harmonic mitigation selection, with worked examples for different industrial load types. King Saud University publication.

Чак и хармонична резонанца- необичан проблем

Chemical plant using large static converters for electrochemical processes experienced repeated harmonic filter failures. Investigation revealed even harmonic resonance — an unusual problem typically found only in uncontrolled rectifiers or systems with DC offset. The even harmonics were caused by asymmetrical firing of the converter’s thyristors, creating 2nd and 4th harmonic currents that the filter was not designed to handle.

Хармоника филтера дизајн за ублажавање Два Ресонант бодова у дистрибутивној мрежи

South African distribution network with two resonant points at different harmonic orders — a single-tuned filter addresses one resonance but can amplify the other. Case from Cape Peninsula University of Technology documents the filter design process for a network with two resonant frequencies, requiring a carefully detuned double-tuned filter to address both simultaneously.

Кондензатор Фаилуре Аналисис (Еатон)

A steel processing plant experienced unexplained capacitor failures and fuse operations in an automatically switched capacitor bank. Eaton Engineering investigation revealed harmonic resonance between the capacitor bank and system impedance — at a specific harmonic order, the impedance was amplified, overloading the capacitors well beyond their rated capability. Classic harmonic-capacitor resonance case with full analytical solution.

Статички конвертори и Повер Куалити

Laboratory measurements on a 2.2 kW adjustable speed drive subjected to controlled voltage dips of varying magnitude and duration. The ASD’s DC bus capacitors and ride-through capability are characterised — showing the boundary between ride-through and trip as a function of sag depth and duration. Provides the experimental basis for ASD immunity specification in sensitive industrial applications.

Жељезара уземљење Систем

A steel factory in northern Italy had all laboratory electronic equipment behaving erratically — seemingly without cause. Investigation revealed constructive defects in the earthing system creating large current loops. With heavy currents flowing through the earth return path, the potential difference between equipment earths was sufficient to cause data corruption and equipment malfunction throughout the plant.

Дистрибутед генерација и Квалитет електричне енергије

Belgian MV distribution network segment used to study the impact of distributed generation technologies (wind, ПВ, CHP) on power quality and voltage stability. Four cable feeders from a 14 МВА 70/10 kV transformer. Analysis shows how DG penetration affects voltage profiles, harmonic injection, and voltage stability — with practical implications for network planning with high DG penetration.

Напон и струја хармоници (Вилеи & Синови)

Six-pulse converter transformer selection and rating when harmonic spectrum is known. John Wiley Handbook of Power Quality chapter covers K-factor calculation, additional loss estimation, and de-rating methodology for transformers feeding rectifier loads. Provides the calculation procedure engineers need to correctly specify transformers for non-linear load environments.

АДФ Побољшава динамички тестни кревет (ЦОМСИС АБ)

Dynamic test bench with programmable loading patterns produced harmonics up to the 100th order and significant voltage notching. Comsys ADF Active Harmonic Filter installation reduced notching and harmonic distortion, restoring supply quality to other equipment on the same transformer. A duplicate of case 2328 with slightly different background — Comsys vs. Active Harmonic Filters branding.

АДФ Сигурна производња хране ублажавањем хармоника (ЦОМСИС АБ)

REWE Dortmund distribution centre — rebuilt and expanded butcher facility with high VFD density — experienced harmonics causing machinery malfunctions. Comsys ADF active harmonic filter brought current THD within acceptable limits and eliminated the machinery problems. Duplicate of case 2336 with Comsys branding — same REWE Dortmund facility, same solution.

АДФ повећава производњу постројења за пречишћавање воде за 30% (ЦОМСИС АБ)

GRYAAB Ryaverket sewage works in Gothenburg — one of Scandinavia’s largest treatment plants — used VFD-controlled pumps. Comsys ADF active harmonic filter optimised VFD electrical behaviour, allowing 30% more fluid processing capacity during peak periods with simultaneous energy savings. Duplicate of case 2334 with Comsys branding — same Gothenburg facility.

Побољшање квалитета електричне енергије и уштеда енергије у текстилној индустрији коришћењем солид-стате хармоника филтера

Solid-state harmonic filter application in a textile manufacturing plant — reducing harmonic current injection from VFD-driven machinery. The filter also improved power factor, reducing reactive power charges from the utility. Available as an external linked technical document.

Висока-Ордер хармоници (Хиоки)

Power supplies with semiconductor control devices generate high-frequency noise above several kHz — high-order harmonics that cause equipment malfunction and radio/TV interference. HIOKI measurement at 1-phase 100V shows the frequency spectrum, resonance amplification effects, and the threshold at which the noise becomes dangerous to connected equipment.

Прилива и одлива хармоника (Хиоки)

HIOKI technical guide to determining whether harmonics are flowing from a facility into the grid or from the grid into the facility — the fundamental question for harmonic source attribution. Covers power direction measurement methods, Japanese utility guideline compliance assessment, and field measurement examples showing both inflow and outflow scenarios with the HIOKI PW3198.

Неисправна медицинска машина (Метиљ)

A building manager with widespread electrical malfunctions and three electricians who quit — none could identify the problem. A systematic approach starting with current measurement revealed a tripped GFCI with high neutral current feeding a malfunctioning medical device. Classic case demonstrating that systematic PQ investigation beats component replacement as a troubleshooting strategy.

Квар руралног трансформатора (Метиљ)

Rural transformer failure at the end of a medium-voltage feeder serving an apartment complex, dairy farm, and golf course. Fluke investigation found the transformer failed from sustained overloading combined with harmonic current from a variable-speed pump at the dairy farm. Demonstrates that harmonics contribute to transformer failure through additional winding losses — even in rural settings withcleanloads.

Неисправан семафор (Метиљ)

Traffic light controller at a main town intersection malfunctioning randomly — sometimes working, sometimes causing long unexplained delays in one direction. Fluke 43B investigation found voltage unbalance and harmonics from a nearby industrial customer on the same distribution transformer. The traffic light controller was sensitive to supply quality — a finding not obvious without measurement.

Кварови мотора у машинској радионици (Метиљ)

Machine shop motors failing repeatedly despite no change in mechanical loads and other equipment on the same service working normally. Motor rewind shop supervisor used Fluke measurement to identify voltage unbalance plus harmonic distortion — classic combination that produces negative-sequence rotor currents, dramatically increasing motor winding temperature and shortening motor life.

Евалуација Осветљење баласт (Метиљ)

Lighting maintenance in large facilities is a major cost — especially with high ceilings requiring personnel lifts. This Fluke case study evaluates whether replacing existing ballasts with electronic ballasts reduces maintenance costs enough to justify the capital investment, using measured power factor, harmonic content, and lamp life data to build the economic case.

Полуталасни исправљач (Метиљ)

A school district transformer making achatteringnoise with heavily loaded secondary — loads including lights, electric heat, and computers. A half-wave rectifier in a fan motor heater combination was generating DC current and even harmonics, causing the transformer core to saturate asymmetrically and vibrate audibly. Classic even harmonic / DC injection problem from a defective single-phase load.

Ветар генерација Квалитет електричне енергије & Питања Интерцоннецт (Дранетз)

Wind generation plant interconnection requires assessment of harmonics, треперење, флуктуација напона, frequency deviation, and fault ride-through capability. Dranetz monitoring solutions cover both temporary commissioning assessment and permanent 24/7 monitoring for continuous interconnection compliance verification on wind farms of any size.

Студија случаја квара у фабрици стакла код електронских контрола (Дранетз)

A glass factory imported from a 60 Hz country to a 50 Hz country suffered repeated electronic control failures, reducing production capacity by 50%. Voltmeters and simple monitors failed to capture the cause. Full PQ monitoring eventually revealed voltage transients and harmonic distortion incompatible with the 60 Hz-designed electronics — a frequency migration problem compounded by poor power quality.

Течни гас и пумпа / Пипелине Апликације (Амерички суперпроводљив)

Pipeline pump stations are moving to larger motors — 4160V in the 2,000–4,000 HP range, 15kV-class at 8,000–15,000 HP — creating significant flicker, хармоничан, and reactive power management challenges. American Superconductor’s PQ-SVC system provides dynamic reactive compensation enabling larger motor sizes at existing substations without requiring substation upgrades.

Хармонични проблеми у казину

Michigan casino with 1000 slot machines planned 500 more — but the utility measured 5% THDv at the PCC and demanded correction before allowing the expansion. Interference on CCTV security monitors was also traced to harmonic distortion. Arteche zigzag transformer eliminated third-harmonic triplen currents, allowing the casino expansion to proceed within the utility’s voltage distortion limit.