Distorsion supraharmonique dans les réseaux MT et BT - Quatre effets négatifs documentés et l'écart des limites

Four documented negative effects of supraharmonic distortion (2–150 kHz) on MV and LV distribution networks: power loss and heating from skin effect, dielectric material aging at accelerated stress cycle rates, MV cable termination failures from combined dielectric stress and local heating, and PLC interference in smart metering and demand response systems. Constatation clé: MV/LV transformer transfer ratio is 0.5–3.0 — some supraharmonic components are amplified crossing from MV to LV. Strong correlation measured at substations 16 km l'un de l'autre. No planning or compatibility limits currently exist above 9 kHz.

Recharge des véhicules électriques et qualité de l’énergie dans les réseaux résidentiels BT – du chargeur individuel à la pénétration de la flotte

Niveau 2 Chargeurs EV à 7.2 kW produit un courant dominant de troisième harmonique qui s'accumule dans le conducteur neutre et provoque un déséquilibre de tension augmentant avec la distance du transformateur. La simulation Monte Carlo sur plusieurs niveaux de pénétration montre une facturation incontrôlée à 30%+ la pénétration peut pousser VUF au-delà 2% aux extrémités des bus. La recharge intelligente élimine le problème sans atténuation matérielle. Les chargeurs de véhicules électriques produisent également des émissions supraharmoniques (2–150 kHz) qui peut perturber les communications CPL destinées à gérer lui-même la recharge des véhicules électriques.

Production d'énergie solaire (HIOKI)

Solar PV power conditioners maintain output by monitoring grid voltage and frequency — but malfunction when grid voltage rises above threshold or frequency deviates. Problems include inverter trips, inability to sell back power due to overvoltage, and high-order harmonic injection from neighbouring PV systems. Field measurement identifies the dominant disturbance type.

Bruit conducteur (HIOKI)

Conductive noise — high-frequency electrical disturbances spreading through power, signal, and ground cables from lightning surges, les décharges électrostatiques, and high-order harmonics — causes equipment malfunction and radio/TV interference in neighbouring premises. HIOKI measurement techniques covering up to 100 MHz identify the noise frequency band and propagation path for targeted mitigation.

Haute-harmoniques (HIOKI)

Les alimentations électriques dotées de dispositifs de commande à semi-conducteurs génèrent un bruit haute fréquence supérieur à plusieurs kHz — des harmoniques d'ordre élevé qui provoquent un dysfonctionnement de l'équipement et des interférences radio/TV.. La mesure HIOKI à 100 V monophasé montre le spectre de fréquence, effets d'amplification de résonance, et le seuil à partir duquel le bruit devient dangereux pour les équipements connectés.