Ruido & EMI

Electrical noise, interferencias electromagnéticas, conducted and radiated disturbances

Efecto de las sobrecargas inducidas por servicios públicos-en una fábrica de acero con variadores de velocidad (Puesta a tierra Práctico, Bonding, Blindaje y protección contra sobretensiones)

A steel mill with variable speed drives experienced frequent VSD tripping with “sobretensión en la línea de CA” indication despite normal steady-state voltage. Utility-induced switching surges — invisible to RMS voltmeters — were the root cause. Case demonstrates why true PQ monitoring with transient capture is essential in facilities with long cable runs and VSD loads.

Fábrica de Acero Sistema de puesta a tierra

A steel factory in northern Italy had all laboratory electronic equipment behaving erratically — seemingly without cause. Investigation revealed constructive defects in the earthing system creating large current loops. With heavy currents flowing through the earth return path, the potential difference between equipment earths was sufficient to cause data corruption and equipment malfunction throughout the plant.

Sistema de puesta a tierra de cobre protege Mt. Washington Torres (Cobre Desarrollo Association Inc)

Mt. Washington’s communication towers serving northern New England — carrying TV, radio, telephone, FAA air traffic control, and emergency services — were vulnerable to lightning until 1993. A comprehensive copper grounding system redesign eliminated lightning-related equipment damage and downtime, demonstrating the economic case for proper grounding in high-exposure communication infrastructure.

Ruido conductiva (HIOKI)

Conductive noise — high-frequency electrical disturbances spreading through power, signal, and ground cables from lightning surges, descarga electrostática, and high-order harmonics — causes equipment malfunction and radio/TV interference in neighbouring premises. HIOKI measurement techniques covering up to 100 MHz identify the noise frequency band and propagation path for targeted mitigation.

Ruido de onda de voltaje & UPS Switching (HIOKI)

Eighteen days of monitoring on a 1-phase 100V circuit recorded 68 identical waveform distortion events, subsequently classified into two types: UPS switching transients and persistent waveform noise. The systematic waveform comparison technique demonstrates how event classification reveals root cause — the UPS was not returning to sine wave output after switching.

El mal funcionamiento de la máquina médica (Chiripa)

A building manager with widespread electrical malfunctions and three electricians who quit — none could identify the problem. A systematic approach starting with current measurement revealed a tripped GFCI with high neutral current feeding a malfunctioning medical device. Classic case demonstrating that systematic PQ investigation beats component replacement as a troubleshooting strategy.

El incumplimiento de cristal Fábrica de Estudio Electronic Case Controls (Dranetz)

A glass factory imported from a 60 Hz country to a 50 Hz country suffered repeated electronic control failures, reducing production capacity by 50%. Voltmeters and simple monitors failed to capture the cause. Full PQ monitoring eventually revealed voltage transients and harmonic distortion incompatible with the 60 Hz-designed electronics — a frequency migration problem compounded by poor power quality.